Brands

Information

Email Signup



Join our mailing list!







  Home > Altronix > Power Supplies >

Altronix AL300ULM Access Power Distribution Module w/ Power Supply/Charger
Altronix AL300ULM Access Power Distribution Module w/ Power Supply/Charger (5 PTC Class 2 Outputs, 12/24VDC @ 2.5A, FAI, 115VAC, BC300 Enclosure)


 
Price: $177.88

Quantity in Stock:(Out of Stock)

Product Code: AL300ULM
Qty:

Description
 
Altronix AL300ULM Access Power Distribution Module w/ Power Supply/Charger (5 PTC Class 2 Outputs, 12/24VDC @ 2.5A, FAI, 115VAC, BC300 Enclosure)

  • AL300ULM multi-output access control power supply/charger is specifically designed for use with access control systems and accessories.
  • This unit converts a 115VAC / 60Hz input into five (5) individually protected Class 2 Rated power limited 12VDC or 24VDC outputs.
  • Each output will route power to a variety of access control hardware devices including Mag Locks, Electric Strikes, Magnetic Door Holders, etc.
  • These outputs will operate in both Fail-Safe and Fail-Secure modes.
  • Controlled trigger input is achieved through normally open (N.O.) or normally closed (N.C.) supervised input or the polarity reversal from an FACP (Fire Alarm Control Panel).
  • A form "C" dry output relay enables HVAC Shutdown, Elevator Recall or may be used to trigger auxiliary devices.

Input:

  • Input 115VAC / 60Hz, 3.5A.
  • Input fuse rated @ 3.5A/250V.
  • Fire Alarm Panel or Access Control System trigger inputs. N.O. or N.C.supervised trigger input and polarity reversal trigger input.

Output:

  • 12VDC or 24VDC selectable outputs.
  • 2.5A supply current.
  • Five (5) (auto-resettable) PTC protected outputs, rated @ 2A.
  • Output relay energizes when unit is triggered (form "C" contact rated 1A @ 28VDC).
  • Filtered and electronically regulated output.
  • Short circuit and thermal overload protection.

Battery Backup:

  • Built-in charger for sealed lead acid or gel type batteries.
  • Automatic switch over to stand-by battery when AC fails.

Supervision:

  • AC fail supervision (form "C" contacts).
  • Notification trigger is selectable for 30 seconds (factory set) or 6 hours.
  • Low battery supervision (form "C" contacts).
  • Battery presence supervision (form "C" contacts).
  • Power fail supervision relay (form "C" contacts).

Visual Indicators:

  • AC input and DC output LED indicators (power supply board).
  • Red LEDs indicate condition of power outputs (multi-output board).
  • Power & input trigger LEDs (multi-output board).

Temperature:

  • Operating: 0° C to 49° C ( 32° F to 120° F ).
  • Storage: - 20° C to 70° C ( -4° F to 158° F ).
  • Relative Humidity 85% +/- 5%.

BTU/Hr (approx.):

  • 12VDC: 15 BTU/Hr.
  • 24VDC: 31 BTU/Hr.
  • System AC input VA requirement: 166.75VA.


Share your knowledge of this product. Be the first to write a review »